Safety analysis on SMART anticipated transient without scram
Description
With TASS/SMR code, safety analyses have been performed on the ATWS(anticipated transient without scram), which is possible to occur in SMART, to identify whether or not SMART satisfies acceptable criteria in ATWS condition. Initiating events considered in safety analyses are loss of feedwater flow, single control rod assembly withdrawal and control rod assembly bank withdrawal. 100% rated core power of beginning of core, middle of core and end of core are established as initial condition. According to analyses results, primary pressure resulted from control rod assembly bank withdrawal event is higher than those resulted from other 2 initiating events. However, there seems to be pressure margin in comparison with pressure criteria on the ATWS, 22.06 MPa
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS-KARP Joint spring meeting
- Imprint Pagination
- [CD-ROM]
- Journal Page Range
- [14 p.]
Conference
- Title
- 2002 joint spring meeting of the KNS-KARP
- Dates
- 23-24 May 2002
- Place
- Gwangju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 34009755
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CONTROL ELEMENTS; FEEDWATER; PWR TYPE REACTORS; REACTOR CORES; SAFETY ANALYSIS; T CODES; TRANSIENTS
- Descriptors DEC
- COMPUTER CODES; ENRICHED URANIUM REACTORS; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS; POWER REACTORS; REACTOR COMPONENTS; REACTORS; THERMAL REACTORS; WATER; WATER COOLED REACTORS; WATER MODERATED REACTORS