Beam decelerations with variable momentum compaction in the Fermilab Antiproton Accumulator
Creators
Description
For the study of charmonium resonances above and including the χc0, Fermilab experiment E-835 required an intense and stochastically cooled antiproton beam with kinetic energies from 8 GeV (the injection energy of the Accumulator) down to 4 GeV. We developed a scheme in which the momentum compaction factor of the machine was changed as the antiprotons were decelerated, so that the energies of interest to the experiment were kept above transition. The scheme was used during the E-835 10-month run of the year 2000. Here we describe the design criteria, operational procedures and diagnostic tools we used to exploit the machine as an efficient antiproton decelerator. The machine performance during data taking is also discussed, in relation to the main experimental requirements
Additional details
Identifiers
- PII
- S0168900203013950;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 506
- Journal Issue
- 3
- Journal Page Range
- p. 205-216
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35001251
- Subject category
- S43: PARTICLE ACCELERATORS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ACCELERATION; ANTIPROTON BEAMS; CHARMONIUM; COMPACTIFICATION; DESIGN; FERMILAB; GEV RANGE 01-10; KINETIC ENERGY; OPERATION; RESONANCE
- Descriptors DEC
- ANTINUCLEON BEAMS; ANTIPARTICLE BEAMS; BEAMS; BOSONS; ELEMENTARY PARTICLES; ENERGY; ENERGY RANGE; GEV RANGE; HADRONS; MESONS; NATIONAL ORGANIZATIONS; QUARKONIUM; US DOE; US ORGANIZATIONS
Optional Information
- Copyright
- Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.