By paper chromatography method, taking 0.9% NaCl (System I) and 85% methanol (System II) as two developing solvent systems, the Rf values of 99mTc, 99mTc-colloid and 99mTc-MDP were determined. They are respectively 0.68≅0.76, 0 and 1.0 in System I; 0.6 ≅ 0.7, 0 and 0 in System II. This result indicates 99mTc-colloid can be separated from 99mTc and 99mTc-MDP with System I; 99mTc separated from 99mTc-colloid and 99mTc-MDP with System II. The result indicates the radiochemical purity of 99mTc-MDP can be determined by the two developing solvent systems and developing under nitrogen pressure in System I. The method is convenient, feasible and effective

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
17
Journal Issue
5
Journal Page Range
p. 301-303.
ISSN
0253-3219
CODEN
NUTEDL