Published January 12, 2015 | Version v1
Journal article

3D dose verification with polymer gel detectors of brain-spine match line for proton pencil beam cranio-spinal: A preliminary study

  • 1. Department of Radiation Oncology, University of Pennsylvania Medical Center, Philadelphia, PA (United States)
  • 2. MGS Research, Inc., Madison, CT 06443 (United States)

Description

This paper is intended as a preliminary study to demonstrate the quality assurance benefits from polymer gel detectors for proton pencil beam cranio-spinal treatments. A stable gel type was selected for protons to suppress the LET dependence at the end of the Bragg peak. The depth dose distributions in the gels were examined with regard of its dose dependences and compared to baseline measurements. The preliminary experimental results indicate polymer gel detectors may be able to verify dose in three dimensions along match line for proton therapy treatments

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/573/1/012020

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
573
Journal Issue
1
Journal Page Range
[4 p.]
ISSN
1742-6596

Conference

Title
8. International Conference on 3D Radiation Dosimetry
Acronym
IC3DDose
Dates
4-7 Sep 2014
Place
Ystad (Sweden)