Published 2011 | Version v1
Miscellaneous Open

Use of VAP3D software for production and manipulation of synthetic radiographies of anthropomorphic models

  • 1. Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)
  • 2. Universidade Federal de Roraima (DMAT/UFRR), Boa Vista, RR (Brazil). Dept. de Matematica
  • 3. Universidade de Pernambuco (EPP/UPE), Recife, PE (Brazil). Escola Politecnica de Pernambuco
  • 4. Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil)
  • 5. Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

Description

The Grupo de Dosimetria Numerica has developed exposure computational models (ECM) involving a Monte Carlo code and voxel phantoms to simulate various situations of internal and external exposure to ionizing radiation. Most analyses of the produced results are presented in tables and graphics formats. An alternative to this traditional way of analyzing results is to save voxels of Regions of Interest (ROI) of the phantom irradiated with information like the location of the voxel and the energy deposited in it during the simulation. Such information can be saved to a text file and later turned into 3D objects. In this paper the VAP3D software has been used to read text files produced in simulations using the ECM of DEN (Nuclear Energy Dept. - UFPE), converting them into binary files of the type RAW, and visualize them. In order to reflect the radiosensitivity of the organs and tissues suggested by ICRP-60, for conversion of text file to binary, of the energy deposited values are multiplied by the weighting factor of the tissue to which the voxel belongs. The result of the multiplication is normalized to the interval [0, 255]. The files transformed are referred herein as synthetic radiographies. In VAP3D software, it is possible to generate stacks from theses radiographies in transverse, sagittal and coronal directions. In order to illustrate the production of synthetic radiographies, some images are presented in this paper, and dosimetric results are obtained from a variety of ROIs of the phantoms of DEN for radiological exams. (author)

Files

42109449.pdf

Files (1.0 MB)

Name Size Download all
md5:c87e40c06e168901d304e9e11468860b
1.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
INIS-BR--10617

Conference

Title
International nuclear atlantic conference. Nuclear energy: new jobs for a better life; 17. ENFIR: Meeting on nuclear reactor physics and thermal hydraulics; 10. ENAN: Meeting on nuclear applications; 2. ENIN: Meeting on nuclear industry
Acronym
INAC 2011
Dates
24-28 Oct 2011
Place