Published May 2012 | Version v1
Journal article

Single- and Dual-Channel DPSK Signal Amplitude Regeneration Based on a Single Semiconductor Optical Amplifier

  • 1. Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China)

Description

We experimentally demonstrate that, based on operational condition optimization, a common quantum well (QW) semiconductor optical amplifier (SOA) has the ability of amplitude regeneration for return-to-zero (RZ) differential phase shift keying (DPSK) signals. For a single-channel RZ-DPSK regeneration scheme, a significant eye-opening enhancement and a negative power penalty of about 1.0 dB are obtained. For dual-channel RZ-DPSK regeneration, it can also be found that the eye-opening improvement and power penalty decrease in each channel. In addition, the DPSK regeneration scheme based on a single QW SOA is quite simple and stable. (fundamental areas of phenomenology(including applications))

Availability note (English)

Available from http://dx.doi.org/10.1088/0256-307X/29/5/054202

Additional details

Publishing Information

Journal Title
Chinese Physics Letters
Journal Volume
29
Journal Issue
5
Journal Page Range
[3 p.]
ISSN
0256-307X
CODEN
CPLEEU

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45003689
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
AMPLIFIERS; AMPLITUDES; OPTIMIZATION; PHASE SHIFT; QUANTUM WELLS; REGENERATION; SEMICONDUCTOR DEVICES; SIGNALS
Descriptors DEC
ELECTRONIC EQUIPMENT; EQUIPMENT; NANOSTRUCTURES