Published November 2019 | Version v1
Report

Design and complete the mass thickness detector for dose-estimated inside product irradiated by 10 MeV electron beam on UELR-10-15S2 accelerator

  • 1. Research and Development Center for Radiation Technology, VINAGAMMA (Viet Nam)

Description

The counter by sodium iodide (NaI) scintillation counters from gamma source were used in estimate the density distribution on product. The dose distribution in-side product irradiated by 10 MeV on UELR-10-15S2 was also estimated. The moving system and controller were designed. The quick density detector had been compare with dose mapping by dosimeter. There was a good agreement between the results of both methods. The mass thickness detector has a meaning in QA/QC electron irradiation processing at VINAGAMMA. (author)

Part of:
The VINATOM - Annual Report for 2018

Additional details

Publishing Information

ISBN
978 604 67 1143 8
Imprint Title
The VINATOM - Annual Report for 2018
Imprint Pagination
284 p.
Journal Page Range
p. 78-82
Report number
VINATOM-AR--18

Optional Information

Notes
4 refs, 3 tabs, 5 figs.
Secondary number(s)
VINATOM-AR--18-08