Tailoring of magnetic imaging system for nondestructive inspection

  • 1. R and D Center, Tohoku Electric Power Co., Inc. 2-1 Nakayama 7-chome, Aoba-ku, Sendai 981-0952 (Japan)

Description

A previously developed robotic 3D superconducting quantum interference device (SQUID) imaging system, i.e., one that is not stationary but rather the SQUID sensor itself moves or scans along the surface of the object, was improved. A new sharp dewar tail design allows the SQUID sensor itself scans in 3D by travelling over the free-form surface areas of an object during testing without the need for magnetic shielding. The magnetic flux resolution was slightly better than that of the previous system when SQUID sensor was mounted on an insulating material, sapphire instead of copper

Additional details

Identifiers

DOI
10.1016/j.jmmm.2006.10.1023;
PII
S0304-8853(06)02250-5;

Publishing Information

Journal Title
Journal of Magnetism and Magnetic Materials
Journal Volume
310
Journal Issue
2
Journal Page Range
p. e980-e982
ISSN
0304-8853
CODEN
JMMMDC

Conference

Title
17. international conference on magnetism
Dates
20-25 Aug 2006
Place
Kyoto (Japan)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
39027047
Subject category
S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COPPER; DEWARS; INSPECTION; MAGNETIC FLUX; MAGNETIC SHIELDING; NONDESTRUCTIVE ANALYSIS; ROBOTS; SAPPHIRE; SENSORS; SQUID DEVICES; SURFACE AREA; SURFACES
Descriptors DEC
CHEMICAL ANALYSIS; CONTAINERS; CORUNDUM; ELECTRONIC EQUIPMENT; ELEMENTS; EQUIPMENT; FLUXMETERS; MEASURING INSTRUMENTS; METALS; MICROWAVE EQUIPMENT; MINERALS; OXIDE MINERALS; SHIELDING; SUPERCONDUCTING DEVICES; SURFACE PROPERTIES; TRANSITION ELEMENTS

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.