Published November 1988 | Version v1
Journal article

Proportional counters as low energy photon detectors

  • 1. Wisconsin Univ., Madison (USA). Dept. of Physics

Description

We have investigated the response of an argon-methane proportional counter to monochromatic X-rays in the range 99-277 eV. The apparent nonlinearities in mean pulse height as a function of photon energy and the detailed shape of the pulse height distribution for each energy can be predicted quite precisely using the extensive atomic data available for argon. Based on this understanding, we propose a semiempirical system for using a limited amount of calibration data to predict the full response of counters employing less well characterized gasses. Such accurate models of proportional counter response are required to maximize the spectral information that can be derived from observed pulse height distributions. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research, Section A
Journal Volume
272
Journal Issue
3
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
800-813
ISSN
0168-9002
CODEN
NIMAE

Optional Information

Contract/Grant/Project number
Grant NAG 5-629