Published December 1990 | Version v1
Journal article

Shielding of the patient's gonads during intramedullary interlocking femoral nailing

  • 1. Harbor/Univ. of California, Los Angeles Medical Center, Torrance (USA)

Description

Levels of exposure to radiation were recorded at sixty sites in fifteen patients during intramedullary interlocking femoral nailing. Radiation film dosimeters were placed at four gonadal sites on each subject. A standard male-gonad cup or a pelvic drape of 0.5-millimeter-thick lead-equivalent was put in place to shield the gonads. A second set of four dosimeters was placed external to the shield to approximate unprotected exposure. The total duration of the fluoroscopy averaged five minutes (range, thirty seconds to fourteen minutes). The total exposure to radiation external to the shield was 35 +/- 34 millirems at the male gonadal sites and 17 +/- 11 millirems at the female gonadal sites. With use of the gonadal shield, exposure to radiation was not measurable in thirteen of the fifteen patients. The differences between the exposures of the shielded and unshielded sites to radiation were statistically significant (p less than 0.001). The highest level of gonadal exposure was found with the treatment of proximal femoral fractures and with the use of statically locked nails. Regardless of the conditions, and for all types of fractures and locations, our results demonstrated that gonadal shielding is justified

Additional details

Publishing Information

Journal Title
Journal of Bone and Joint Surgery, American Volume
Journal Volume
72
Journal Issue
10
Series
J. Bone Jt. Surg., Am. Vol.
Journal Page Range
1523-1526
ISSN
0021-9355
CODEN
JBJSA