Pressure transducer used for measuring close-in shock waves of nuclear explosions in the atmosphere

Description

This paper introduces a variable reluctance pressure transducer. It has been successfully used for the measurement of close-in shock waves of nuclear explosions in the atmosphere. This transducer's highest pressure range is 100kg/cm2 and its response rise time for all ranges is lms. It uses a specially made oil-filled pressure which allows the transducer to be able to realize underground installation. In this way, it can endure the intense nuclear radiation of nuclear explosions without losing its fast speed response characteristics. This transducer has undergone a series of environmental tests and dynamic standardizations. Therefore, it was used to measure the complete waveform of shock wave overpressure in areas near the fire ball of nuclear explosions. This paper lists the test data of a group of nuclear explosion tests

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE85007028.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
LA-tr--85-4

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16061135
Subject category
S42: ENGINEERING;
Descriptors DEI
ATMOSPHERIC EXPLOSIONS; NUCLEAR EXPLOSIONS; PRESSURE MEASUREMENT; SHOCK WAVES; TRANSDUCERS
Descriptors DEC
EXPLOSIONS