Leakage through gaps around shielding windows in radiotherapy treatment rooms
Creators
- 1. UKAEA Risley Nuclear Power Development Establishment. Process Technology and Safety Directorate
- 2. Churchill Hospital, Oxford (UK)
Description
Radiation streaming down gaps between shielding windows and walls of radiotherapy treatment rooms has been investigated. The calculations were based on a cobalt-60 source and were performed with the computer code RANKERN. The dose rate near the exit of the gap on the cold side of the window was calculated as the sum of contributions from direct line of sight and radiation scattered off the faces of the gap, using albedo data. The RANKERN code employs point kernel equations which are solved by a stochastic integration method. The paper demonstrates that although for a single element window small gaps could lead to significant leakage of radiation, for a double or triple element window, even a gap of ten millimetres would result in a dose rate no greater than that through the surrounding concrete. (author)
Additional details
Publishing Information
- Journal Title
- Phys. Med. Biol.
- Journal Volume
- 29
- Journal Issue
- 6
- Series
- Phys. Med. Biol.
- Journal Page Range
- 711-718
- ISSN
- 0031-9155
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 15061454
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE; S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- DOSE RATES; HOSPITALS; LEAKS; R CODES; RADIATION DOSES; RADIATION PROTECTION; RADIATION STREAMING; RADIOTHERAPY; SHIELDING; STOCHASTIC PROCESSES
- Descriptors DEC
- BUILDINGS; COMPUTER CODES; MEDICAL ESTABLISHMENTS; MEDICINE; THERAPY