Published February 2017 | Version v1
Journal article

A method to determine the impact of reduced visual function on nodule detection performance

  • 1. University of Salford, Salford M6 6PU (United Kingdom)
  • 2. Public Health Research Center, National School of Public Health, NOVA University of Lisbon (Portugal)
  • 3. Lisbon School of Health Technology, 1990-096 Lisbon (Portugal)
  • 4. Karolinska Institute, SE-171 77 Stockholm (Sweden)

Description

Purpose: In this study we aim to validate a method to assess the impact of reduced visual function and observer performance concurrently with a nodule detection task. Materials and methods: Three consultant radiologists completed a nodule detection task under three conditions: without visual defocus (0.00 Dioptres; D), and with two different magnitudes of visual defocus (−1.00 D and −2.00 D). Defocus was applied with lenses and visual function was assessed prior to each image evaluation. Observers evaluated the same cases on each occasion; this comprised of 50 abnormal cases containing 1–4 simulated nodules (5, 8, 10 and 12 mm spherical diameter, 100 HU) placed within a phantom, and 25 normal cases (images containing no nodules). Data was collected under the free-response paradigm and analysed using Rjafroc. A difference in nodule detection performance would be considered significant at p < 0.05. Results: All observers had acceptable visual function prior to beginning the nodule detection task. Visual acuity was reduced to an unacceptable level for two observers when defocussed to −1.00 D and for one observer when defocussed to −2.00 D. Stereoacuity was unacceptable for one observer when defocussed to −2.00 D. Despite unsatisfactory visual function in the presence of defocus we were unable to find a statistically significant difference in nodule detection performance (F(2,4) = 3.55, p = 0.130). Conclusion: A method to assess visual function and observer performance is proposed. In this pilot evaluation we were unable to detect any difference in nodule detection performance when using lenses to reduce visual function. - Highlights: • Nodule detection performance was assessed with and without visual defocus. • Lenses were successfully applied to induce a reduction in visual acuity. • A method to reduce visual acuity and assess observer performance is presented.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radi.2016.07.002

Additional details

Identifiers

DOI
10.1016/j.radi.2016.07.002;
PII
S1078-8174(16)30046-3;

Publishing Information

Journal Title
Radiography (London 1995)
Journal Volume
23
Journal Issue
1
Journal Page Range
p. 19-24
ISSN
1078-8174

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49034520
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CONSULTANTS; EVALUATION; IMAGES; PERFORMANCE; PHANTOMS; RADIATION DETECTION; SIMULATION
Descriptors DEC
DETECTION; MOCKUP; PERSONNEL; STRUCTURAL MODELS

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.