Published October 1, 2016 | Version v1
Journal article

A comparison of emerging gamma detector technologies for airborne radiation monitoring

  • 1. AIR Division, National Physical Laboratory, Hampton Road, Teddington, TW11 0LW (United Kingdom)

Description

This paper presents a comparison of new and emerging gamma detector technologies that have the potential to improve in-situ dose and radioactivity-in-air measurements for national monitoring networks. Five detectors were chosen for investigation; LaBr3(Ce), CeBr3, SiPM-CsI(Tl), Cd(Zn)Te and electromechanically-cooled HPGe. These detectors represent the full range of the price-performance matrix. Comparisons have been made of energy resolution, detection efficiency and minimum detectable activity by exposing each detector to a mixed radionuclide source drop-deposited across a filter. Other factors, such as internal radioactivity, linearity, size and cost have also been considered. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/763/1/012010

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
763
Journal Issue
1
Journal Page Range
[7 p.]
ISSN
1742-6596

Conference

Title
2.workshop on the applications of novel scintillators for Research and Industry
Acronym
ANSRI 2016
Dates
11-13 May 2016
Place
Dublin (Ireland)