Application of probabilistic safety assessment to the pipe rupture incident at Hamaoka Unit-1

  • 1. Nuclear Power Engineering Corp., Institute of Nuclear Safety, Tokyo (Japan)
  • 2. Ministry of Economy, Trade and Industry, Nuclear and Industrial Safety Agency, Tokyo (Japan)

Description

On November 7, 2001, a pipe rupture occurred in the steam condensation line of the residual heat removal system at the Hamaoka Unit-1 while operating at rated power, resulting in steam release with radioactivity into the reactor building and the high pressure coolant injection being unavailable. The reactor was manually shut down immediately after the pipe rupture and there was no radioactive release into the environment. Although this incident was not safety significant, the type of rupture was unprecedented. Thus, the regulatory body, the Nuclear and Industrial Safety Agency (NISA), investigated event causes and examined corrective actions for preventing recurrence, and issued the report describing the investigation results, on May 13, 2002. At the NISA's request, the Nuclear Power Engineering Corporation (NUPEC) evaluated the safety significance of the incident and the effectiveness of corrective actions from the risk point of view by carrying out the Probabilistic Safety Assessment (PSA), that is, the estimation of the core damage frequencies (CDFs). The results showed that the incident has no risk significance and that the individual corrective actions would not lead to any significant increase in CDFs. The present study is the first PSA application to the regulatory decision-making process in Japan. (author)

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
41
Journal Issue
1
Journal Page Range
p. 77-85
ISSN
0022-3131

Optional Information

Notes
8 refs., 5 figs., 2 tabs.