Published October 1998
| Version v1
Miscellaneous
Evaluation of the natural circulation capability test results for Ulchin nuclear power plant unit 3
Creators
- 1. Korea Power Engineering Company, Inc., Taejon (Korea, Republic of)
- 2. KEPCO, Ulchin (Korea, Republic of)
Description
During the Power Ascension Test (PAT) period, the transient tests related to the natural circulation capability were successfully completed for Ulchin Nuclear Power Plant Unit 3 (UCN 3). The tests were successfully completed by meeting all acceptance criteria. The post-trip PCS shows good performance as designed and the measured natural circulation capacity was demonstrated to be adequate for the core decay heat removal for UCN 3
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the Korean Nuclear Society autumn meeting
- Imprint Pagination
- [CD-ROM]
- Journal Page Range
- [5 p.]
Conference
- Title
- 1998 autumn meeting of the Korean Nuclear Society
- Dates
- 30-31 Oct 1998
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 32066958
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- AFTER-HEAT REMOVAL; EVALUATION; HEAT TRANSFER; NATURAL CONVECTION; NUCLEAR POWER PLANTS; TRANSIENTS; ULCHIN-3 REACTOR
- Descriptors DEC
- CONVECTION; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; HEAT TRANSFER; MASS TRANSFER; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; REMOVAL; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 5 refs, 1 tab