Proposed Strategies for DWPF Melter Off-Gas Surge Control

Description

Off-gas surging is inherent to the operation of slurry-fed melters. Although the melter design and the feed chemistry are both known to significantly affect off-gas surging, the frequency and intensity of surges are in essence unpredictable. In typical off-gas surges, both condensable and non condensable flows spike simultaneously. Condensable or steam surges have been observed to occur as the boiling water layer occasionally falls into the crevices of the cold cap or flows over the edges of the cold cap, thereby coming in contact with the melt surface. The resulting steam surges can pressurize the melter considerably and, therefore, are responsible for the bulk of pressure transients that propagate throughout the off-gas system. The non condensable surges occur as the calcine gases that have been accumulating within the cold cap finally build up enough pressure to be released through the temporary openings of the cold cap. The analysis of off-gas data has shown that over 90 of the gas released during a surge is due to steam.1 Therefore, it is essential to have a large inventory of water in the cold cap for any significant pressure spikes to occur. With the Melter 2 vapor space temperature typically running at 720C, the water layer in the cold cap will quickly evaporate once the feeding stops, and the potential for any large pressure spikes should practically cease to exist. The analysis also showed that large pressure spikes well above 2 inches H2O cannot occur under the steam surge scenarios described above. More severe conditions should prevail and one such condition would be that the feed materials form a mound with a growing lake on top, while the melt below remains very fluidic due to its low viscosity, thus resulting in greater movements both in the lateral as well as vertical directions. Once the mound begins to grow, its rate should accelerate, since the heat transfer rate to the upper regions of the cold cap is inversely proportional to the cold cap thickness. Then, when the mound reaches some critical mass, it may begin sink into the bulk melt or tip over, thereby creating a condition almost like a steam explosion

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/833397-MlgaFx/native/

Additional details

Publishing Information

Imprint Pagination
[vp.]
Report number
WSRC-TR--2004-00156

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
36011312
Subject category
S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
BOILING; CHEMISTRY; CRITICAL MASS; DESIGN; GASES; HEAT TRANSFER; OFF-GAS SYSTEMS; OPENINGS; STEAM; SURGES; THICKNESS; TRANSIENTS; VISCOSITY; WATER
Descriptors DEC
DIMENSIONS; ENERGY TRANSFER; FLUIDS; HYDROGEN COMPOUNDS; MASS; OXYGEN COMPOUNDS; PHASE TRANSFORMATIONS

Optional Information

Contract/Grant/Project number
AC--09-96SR18500
Funding organization
US Department of Energy (United States)