Published 2018 | Version v1
Journal article

Monitoring the capacitor charge voltage in the pulse voltage generator using the accelerator of relativistic electron beams

  • 1. National Science Center ''Kharkov Institute of Physics and Technology'', Kharkov (Ukraine)

Description

Noise-protected high charge voltage meter was manufactured using terminal capacitors of the four-channel pulse voltage generator (PVG). The noise protection is provided by the use of communication lines with fiberoptic cables. This measuring device is successfully used for the relativistic electron beam (REB) accelerator 'Temp-B and it provides the measurement accuracy of ∼ 0.5% in the electromagnetic noise environment

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki
Journal Issue
no.4-116
Journal Page Range
p. 59-61
ISSN
1562-6016