Resonance Control Cooling System for the APT/LEDA RFQ
Description
The Radio Frequency Quadrupole (RFQ) resonance control cooling system (RCCS) for the Low Energy Demonstration Accelerator (LEDA) in support of the Accelerator Production of Tritium (APT) is described. Constant flow regulating valves to distribute the required flow to the 424 channels and to permit use of centrifugal pumps is discussed. Control system schema are described to regulate resonance frequency during steady state operation
Availability note (English)
Available from INIS in electronic form; ALSO AVAILABLE FROM OSTI AS DE00001443; NTIS; US GOVT. PRINTING OFFICE DEP.Files
30047949.pdf
Files
(140.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:fe3f5bf11c6c7c7c7af02d565fd585e4
|
140.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 7 p.
- Report number
- KCP--613-6114
Conference
- Title
- 19. International LINAC Conference - LINAC'98
- Dates
- 23-28 Aug 1998
- Place
- Chicago, IL (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 30047949
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COOLING SYSTEMS; DESIGN; MEETINGS; VALVES
- Descriptors DEC
- CONTROL EQUIPMENT; ENERGY SYSTEMS; EQUIPMENT; FLOW REGULATORS