Published August 2018 | Version v1
Journal article

Transient calculation of natural circulation for pool-type research reactor

  • 1. Institute of Nuclear Physics and Chemistry, CAEP, P.O. Box 919-226, Mianyang (China)

Description

The natural circulation capacity is an important parameter that characterizes the safety capability of a nuclear reactor. We calculated the transient characteristics under the conditions with and without emergency cooling system by RELAP5/Mod 3.4, analyzed the transient natural circulation capability of the coolant flow direction reversal process, and acquired the maximum transient transfer capability. The results show:the emergency cooling system reduced fuel and coolant temperatures significantly and improved the safety of the reactor;when the decay power was reduced to 590 kW, the auxiliary pump was turned off and the reactor could be brought into a safe state with natural circulation. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
30
Journal Issue
8
Journal Page Range
[5 p.]
ISSN
1001-4322

Optional Information

Notes
4 figs., 3 tabs., 8 refs.; http://dx.doi.org/10.11884/HPLPB201830.180009