Published August 2018
| Version v1
Journal article
Transient calculation of natural circulation for pool-type research reactor
Creators
- 1. Institute of Nuclear Physics and Chemistry, CAEP, P.O. Box 919-226, Mianyang (China)
Description
The natural circulation capacity is an important parameter that characterizes the safety capability of a nuclear reactor. We calculated the transient characteristics under the conditions with and without emergency cooling system by RELAP5/Mod 3.4, analyzed the transient natural circulation capability of the coolant flow direction reversal process, and acquired the maximum transient transfer capability. The results show:the emergency cooling system reduced fuel and coolant temperatures significantly and improved the safety of the reactor;when the decay power was reduced to 590 kW, the auxiliary pump was turned off and the reactor could be brought into a safe state with natural circulation. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- High Power Laser and Particle Beams
- Journal Volume
- 30
- Journal Issue
- 8
- Journal Page Range
- [5 p.]
- ISSN
- 1001-4322
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 55052935
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ACCIDENTS; CAPACITY; COOLANTS; COOLING SYSTEMS; DECAY; FUELS; NATURAL CONVECTION; PONDS; POOL TYPE REACTORS; PUMPS; R CODES; RESEARCH REACTORS; SAFETY; TRANSIENTS
- Descriptors DEC
- COMPUTER CODES; CONVECTION; ENERGY SYSTEMS; ENERGY TRANSFER; EQUIPMENT; HEAT TRANSFER; MASS TRANSFER; REACTORS; RESEARCH AND TEST REACTORS; SURFACE WATERS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 4 figs., 3 tabs., 8 refs.; http://dx.doi.org/10.11884/HPLPB201830.180009