Published March 1981 | Version v1
Report

Analysis of pumping tests performed in a horizontal rectangular fracture

Creators

  • 1. Bureau de Recherches Geologiques et Minieres, Orleans, France

Description

The analytical solution has been derived for a constant rate uniform flux pumping test in a single horizontal rectangular fracture. The solution is given for the drawdown at the pumped well and at an observation well inside or outside the fracture. A set of type curves which depend on two dimensionless parameters has been drawn. These type curves give the dimensionless drawdown at the pumped well versus the dimensionless time according to the shape factor of the fracture and the dimensionless aquifer thickness. Another set gives the average drawdown along the vertical at an observation well versus dimensionless time depending on the dimensionless distance and the shape factor. For both the drawdown at the pumped well and at an observation well the solution has also been studied for early times and long times in order to derive approximative solutions which are compared to the well known solutions in isotropic aquifers. 5 figures

Additional details

Publishing Information

Imprint Title
Third invitational well-testing symposium: well testing in low permeability environments
Journal Page Range
p. 103-109.
Report number
LBL--12076

Conference

Title
3. invitational well testing symposium.
Dates
26 - 28 Mar 1980.
Place
Oakland, CA, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12632154
Subject category
S58: GEOSCIENCES;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANALYTICAL SOLUTION; AQUIFERS; GEOLOGIC STRUCTURES; HYDROLOGY; PUMPS; WELLS