Published July 2014 | Version v1
Journal article

Analysis of the intrafraction error in image-guided radiotherapy with thoracic esophageal carcinoma

  • 1. Department of Radiation Oncology, Forth Hospital of Hebei Medical University, Shijiazhuang (China)

Description

Objective: The purpose of the study was to use the CBCT to evaluate the intrafraction error and its effect on the target volume and organs at risk. Methods: Twenty-three patients with thoracic esophageal cancer were enrolled into the study. CBCT scans were performed before and at the end of the irradiation to acquire the intrafraction error. Treatment PLAN2 and PLAN3 were simulated according to the intrafraction error. The primary treatment plan was PLAN1. The dosimetry distribution of target volume and organs at risk of the PLAN2 and PLAN3 were analyzed, and then were compared with PLAN1. The data was analysed by one-factor ANOVA and matched t-test. Results: The median intrafraction error (mm) of the upper, the middle and the lower esophageal carcinoma in x, y, z directions were (1.2 ± 1.5) mm, (1.0 ± 1.0) mm, (1.0 ± 1.0) mm (P = 0.138), (1.2 ± 1.0) mm, (1.1 ± 1.0) mm, (1.2 ± 1.0) mm (P = 0.656) and (1.3 ± 0.11) mm, (1.2 ± 1.0) mm, (0.8 ± 0.7) mm (P = 0.003), respectively. The frequency of the intrafraction error within 3 mm in x, y, z directions were 95.2%, 94.5%, 93.9%, respectively. Compared with PLAN1, the volume of the GTV exposed to 100% prescription dose of the PLAN3 decreased by 5.55%. There were 3 patients whose prescription dose of the PTV exposed to 95% volume descend more than 5% in PLAN3. The volume of the lung exposed to 30 Gy was (15.24 ± 2.24)% in PLAN3, which was lower than (15.67 ± 2.28)% in PLAN1 (P = 0.033). There were 4 cases in PLAN2 and 19 cases in FLAN3 whose spinal cord received more than 4500 cGy, the maximum dose were 4517.2 cGy and 5045.2 cGy in PLAN2 and in PLAN3, respectively. Conclusions: The dose distribution of the target volume and organs at risk were influenced by intrafraction error in part. Spinal cord is relatively sensitive to the intrafraction error owing to its tandem belongings. Intrafraction error can result in the over irradiation to the spinal cord for some patients. (authors)

Additional details

Publishing Information

Journal Title
Chinese Journal of Radiation Oncology
Journal Volume
23
Journal Issue
4
Journal Page Range
p. 344-347
ISSN
1004-4221

Optional Information

Notes
6 tabs., 7 refs.; http://dx.doi.org/10.3760/cma.j.issn.1004-4221.2014.04.017