Published May 30, 2008 | Version v1
Journal article

Respirometric kinetic parameter calculations of a batch jet loop bioreactor treating leachate and oxygen uptake rate estimation by DTM

  • 1. Gebze Institute of Technology, Department of Environmental Engineering, Gebze 41400, Kocaeli (Turkey)
  • 2. Yildiz Technical University, Department of Electrical Engineering, Besiktas 34349, Istanbul (Turkey)

Description

A novel circulating jet loop bioreactor adapted for organic matter oxidation has been designed and constructed. In this study, the input was leachate samples collected from Kemerburgaz Odayeri waste landfill site located on the European side of Istanbul. Controlling the jet loop bioreactor to realize high rates of purification depends on maintaining the appropriate loadings and operating conditions. This requires collecting various system data to estimate the dynamics of the system satisfactorily with the aim of keeping certain parameters within the specified range. The differential transform method (DTM) based solution of the state equations reveals the current state of the process so that any deviation in the system parameters can be immediately detected and regulated accordingly. The respirometric method for kinetic parameter calculations for biodegradation has been used for some time. In many studies, the respirometer was designed separately, usually in bench-scale. However, when a separate respirometer is used, the scale effect and parameters that affect the hydrodynamic structure of the system should be taken into consideration. In this study, therefore, the jet loop reactor itself was used as a respirometer. Thus, the kinetic parameters found reflecting the characteristics of microorganisms used for biodegradation would be more realistic. If the main reactor, here the jet loop reactor, would be used as the respirometer, the kinetic parameter changes can easily be monitored in the long run. Using the bioreactor as a respirometer, the most important kinetic parameters, Ks, kd and μmax were found to be 11,000 mg L-1, 0.019 day-1, and 0.21 day-1, respectively. The stoichiometric coefficient, Y, was found to be 0.28 gr gr-1 for the present system

Availability note (English)

Available from http://dx.doi.org/10.1016/j.jhazmat.2007.09.069

Additional details

Identifiers

DOI
10.1016/j.jhazmat.2007.09.069;
PII
S0304-3894(07)01341-6;

Publishing Information

Journal Title
Journal of Hazardous Materials
Journal Volume
153
Journal Issue
3
Journal Page Range
p. 991-998
ISSN
0304-3894
CODEN
JHMAD9

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40036139
Subject category
S54: ENVIRONMENTAL SCIENCES;
Descriptors DEI
BIODEGRADATION; BIOREACTORS; JETS; MICROORGANISMS; ORGANIC MATTER; OXIDATION; OXYGEN; PURIFICATION; SANITARY LANDFILLS; STOICHIOMETRY; UPTAKE; WASTES; WATER TREATMENT
Descriptors DEC
CHEMICAL REACTIONS; DECOMPOSITION; ELEMENTS; MANAGEMENT; MATTER; NONMETALS; WASTE DISPOSAL; WASTE MANAGEMENT

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.