Published June 2004 | Version v1
Journal article

A new ESR dosimeter based on bioglass material

Description

Bioglass (Bio-G) samples were irradiated with 60Co γ-rays to study radicals for dosimetric materials with electron spin resonance (ESR). The ESR spectrum of Bio-G is characterized by two main signals. The first signal at g congruent with 4.3 corresponds to Fe3+ impurities and the second signal at g congruent with 2.0130 with line-width 10.85 G is ascribed as a hole center. The γ-ray dose response and thermal stability were studied to establish the suitability of Bio-G as an ESR dosimeter. A radical formation efficiency, G-value, of 0.53±0.11 was obtained. The lifetime of radicals and the activation energy were estimated from Arrhenius plots to be approximately 255±46 days and 0.71 eV, respectively

Additional details

Identifiers

DOI
10.1016/j.radmeas.2004.01.020;
PII
S1350448704000253;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
38
Journal Issue
3
Journal Page Range
p. 311-315
ISSN
1350-4487
CODEN
RMEAEP

Optional Information

Copyright
Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.