Published 1992 | Version v1
Miscellaneous

Darlington N12 event investigation

  • 1. Ontario Hydro, Toronto, ON (Canada)
  • 2. Atomic Energy of Canada Ltd., Sheridan Park, ON (Canada). CANDU Operations

Description

Following the discovery of damaged fuel from fuel channel N12 in Darlington-2 reactor, an extensive program of inspection of the fuel and fuel channels was undertaken. This paper summarizes the most significant observations and results obtained. 2 refs., 4 figs

Part of:
Proceedings of the 13. annual conference of the Canadian Nuclear Society. V. 2

Additional details

Additional titles

Subtitle (English)
Unit 1 and 2 fuel and fuel channel inspections

Publishing Information

Imprint Title
Proceedings of the 13. annual conference of the Canadian Nuclear Society. V. 2
Imprint Pagination
762 p.
Journal Page Range
[12 p.].
ISSN
0227-1907
Report number
INIS-mf--13961

Conference

Title
32. Annual conference of the Canadian Nuclear Association; 13. Annual conference of the Canadian Nuclear Society.
Dates
7-10 Jun 1992.
Place
Saint John, NB (Canada).

Optional Information