Published 2016
| Version v1
Book
Good practices in radiological protection at Narora Atomic Power Station
Creators
- 1. Health Physics Unit, Narora Atomic Power Station, Bulandshahr (India)
Description
Radiological protection performance of nuclear power plant is assessed by collective exposure, individual average exposure, external/external exposure, personnel/surface contamination and reduction of radioactive wastes. Collective exposure is reduced by integrated comprehensive ALARA program in all aspects of nuclear plant operation and maintenance has reduced collective dose many folds. In the present paper, implementation of new good practices in Radiological Protection is presented
Additional details
Publishing Information
- Publisher
- Indian Association for Radiation Protection
- Imprint Place
- Mumbai (India)
- Imprint Title
- Proceedings of the international conference on radiological safety in workplace, nuclear facilities and environment: book of abstracts
- Imprint Pagination
- 287 p.
- Journal Page Range
- p. 193
Conference
- Title
- 32. international conference on radiological safety in workplace, nuclear facilities and environment
- Acronym
- IARPIC-2016
- Dates
- 22-25 Feb 2016
- Place
- Kalpakkam (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 47088497
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALARA; NARORA-1 REACTOR; NARORA-2 REACTOR; OCCUPATIONAL EXPOSURE; RADIATION MONITORING; RADIATION PROTECTION; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- DOSEMETERS; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MONITORING; NATURAL URANIUM REACTORS; PHWR TYPE REACTORS; POWER REACTORS; REACTORS
Optional Information
- Notes
- 3 figs.