Published September 30, 2004 | Version v1
Journal article

Spectral reconstruction for a 6 MV linear accelerator

  • 1. Instituto de Fisica, UNAM, A.P. 20-364, 01000 D.F. (Mexico)
  • 2. Instituto Nacional de Neurologia y Neurocirugia, D.F. (Mexico)

Description

In this work we present the first results of an x-ray spectral reconstruction for a 6 MV Varian LINAC. The shape of the spectrum will be used in Monte Carlo treatment planning in order to improve the quality and accuracy of the calculated dose distributions. We based our simulation method on the formalism proposed by Francois et al. In this method the spectrum is reconstructed from transmission measurements under narrow beam geometry for multiple attenuator thicknesses. These data allowed us to reconstruct the x-ray spectrum through direct solution of matrix systems using spectral algebra formalism

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
724
Journal Issue
1
Journal Page Range
p. 254-257
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
8. Mexican symposium on medical physics
Dates
17-19 Mar 2004
Place
Guanajuato, Gto. (Mexico)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
36071294
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; ALGEBRA; COMPUTERIZED SIMULATION; DOSIMETRY; GEOMETRY; LINEAR ACCELERATORS; MONTE CARLO METHOD; PLANNING; QUALITY CONTROL; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; TRANSMISSION; X RADIATION; X-RAY SPECTRA
Descriptors DEC
ACCELERATORS; CALCULATION METHODS; CONTROL; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MATHEMATICS; MEDICINE; NUCLEAR MEDICINE; RADIATIONS; RADIOLOGY; SIMULATION; SPECTRA; THERAPY

Optional Information

Notes
(c) 2004 American Institute of Physics