Evaluation of different target/filter combinations in mammography equipment in terms of image quality and mean glandular dose

  • 1. Serviço de Física Médica e Radioproteção/Hospital de Clínicas de Porto Alegre, Porto Alegre, RS (Brazil)

Description

Contrast-to-Noise Ratio (CNR) is one of the most frequently adopted metric for evaluating digital radiographic image quality, being positively correlated with image quality. However, the increase in CNR is conditioned to an increment in Mean Glandular Dose (MGD) in patients. The objective of the study was to verify if the target/filter combination interferes in the relationship between CNR and MGD and, thus, to analyze the best combination to balance image quality and dose in the patient. In total, 98 images of the breast simulator Phantom Mama, for a breast simulating phantom 50mm thick, were acquired for the target/filter combinations Mo/Mo and W/Rh. For all images, we employed a voltage of 28kV and variable current-time product (mAs) in a Siemens Mammomat Inspiration digital mammography equipment. A linear relationship was observed between AGD and mAs with coefficients of determination (R²) equal to 0.99994 (Mo/Mo) and 0.99999 (W/Rh), and a linear relationship between MGD and CNR² with coefficients of determination (R² ) equal to 0.912 (Mo/Mo) and 0.944 (W/Rh). The angular coefficients indicate that the W/Rh combination has a higher CNR² for the same MGD value compared to Mo/Mo. It was concluded that W/Rh combination provides a higher image quality for the same irradiation conditions as the phantom conditions. (author)

Files

54100031.pdf

Files (757.5 kB)

Name Size Download all
md5:e4dd6e8f07568c09506406f051d51690
757.5 kB Preview Download
Part of:
Proceedings of the 26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics

Additional details

Additional titles

Original title (Portuguese)
Avaliação de diferentes combinações alvo/filtro em equipamentos de mamografia em termos de qualidade de imagem e dose glandular média

Publishing Information

Imprint Title
Proceedings of the 26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics
Imprint Pagination
177 p.
Journal Page Range
4 p.
Report number
INIS-BR--24586

Conference

Title
26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics
Dates
8-11 Jun 2022
Place
Fortaleza, CE (Brazil)

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
54100031
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
EQUIPMENT; FILTERS; IMAGES; MAMMARY GLANDS; QUALITY CONTROL; RADIATION DOSES; X RADIATION