Published 2012
| Version v1
Journal article
Axial structure of DC glow discharge negative glow in nitrogen
- 1. V.N. Karazin Kharkiv National University, Kharkiv (Ukraine)
- 2. Scientific Center of Physical Technologies, Kharkiv (Ukraine)
Description
We registered axial profiles of electron temperature, plasma potential and concentration of the direct current glow discharge in nitrogen at different gas pressure and discharge current values. We observed that in a broad range of experimental conditions the plasma concentration experiences 15 - 16 times decrease along the negative glow length. Maximum values of plasma concentration and electron temperature are registered at the cathode end of the negative glow, and the electric field strength is small. On leaving the cathode the plasma concentration and electron temperature in the negative glow are decreasing, here a region with a negative field may also form.
Additional details
Publishing Information
- Journal Title
- Voprosy Atomnoj Nauki i Tekhniki
- Journal Issue
- no.6-82/18
- Journal Page Range
- p. 199-201
- ISSN
- 1562-6016
INIS
- Country of Publication
- Ukraine
- Country of Input or Organization
- Ukraine
- INIS RN
- 45079743
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ELECTRIC CURRENTS; ELECTRON TEMPERATURE; GLOW DISCHARGES; LANGMUIR PROBE; NITROGEN; PLASMA DENSITY; PLASMA POTENTIAL
- Descriptors DEC
- CURRENTS; ELECTRIC DISCHARGES; ELECTRIC POTENTIAL; ELECTRIC PROBES; ELEMENTS; NONMETALS; PROBES