Experiment on performance of upper head injection system with ROSA-II

Description

Thermo-hydraulic behavior in the primary cooling system of a pressurized water reactor with an upper head injection system (UHI) in a postulated loss-of-coolant accident (LOCA) has been studied with ROSA-II test facility. Simulated UHI and internal structures of the pressure vessel were installed to the facility for the experiment. Nine maximum-sized double-ended break tests and one medium-sized split break test were performed for the cold-leg break condition. The results are as follows: (1) Fluid mixing in the upper head is not perfect. (2) Cold water injection into the steam or two-phase fluid causes violent depressurization due to the condensation. Flow pattern in the primary cooling system is largely influenced by the above two. (auth.)

Availability note (English)

MF available from INIS under the Report Number.

Files

8341021.pdf

Files (6.3 MB)

Name Size Download all
md5:464e9d28b86d1bdf7a823d0f33b0e027
6.3 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
169 p.
Report number
JAERI-M--6707