Published March 30, 2006 | Version v1
Journal article

Immobilized enzyme reactor chromatography: Optimization of protein retention and enzyme activity in monolithic silica stationary phases

  • 1. Department of Chemistry, McMaster University, 1280 Main St. West, Hamilton, Ont. L8S 4M1 (Canada)

Description

Our group recently reported on the application of protein-doped monolithic silica columns for immobilized enzyme reactor chromatography, which allowed screening of enzyme inhibitors present in mixtures using mass spectrometry for detection. The enzyme was immobilized by entrapment within a bimodal meso/macroporous silica material prepared by a biocompatible sol-gel processing route. While such columns proved to be useful for applications such as screening of protein-ligand interactions, significant amounts of entrapped proteins leached from the columns owing to the high proportion of macropores within the materials. Herein, we describe a detailed study of factors affecting the morphology of protein-doped bioaffinity columns and demonstrate that specific pH values and concentrations of poly(ethylene glycol) can be used to prepare essentially mesoporous columns that retain over 80% of initially loaded enzyme in an active and accessible form and yet still retain sufficient porosity to allow pressure-driven flow in the low μL/min range. Using the enzyme γ-glutamyl transpeptidase (γ-GT), we further evaluated the catalytic constants of the enzyme entrapped in capillary columns with different silica morphologies as a function of flowrate and backpressure using the enzyme reactor assay mode. It was found that the apparent activity of the enzyme was highest in mesoporous columns that retained high levels of enzyme. In such columns, enzyme activity increased by ∼2-fold with increases in both flowrate (from 250 to 1000 nL/min) and backpressure generated (from 500 to 2100 psi) during the chromatographic activity assay owing to increases in k cat and decreases in K M, switching from diffusion controlled to reaction controlled conditions at ca. 2000 psi. These results suggest that columns with minimal macropore volumes (<5%) are advantageous for the entrapment of soluble proteins for bioaffinity and bioreactor chromatography

Additional details

Identifiers

DOI
10.1016/j.aca.2005.12.066;
PII
S0003-2670(06)00073-0;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
564
Journal Issue
1
Journal Page Range
p. 106-115
ISSN
0003-2670
CODEN
ACACAM

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38073686
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
CHROMATOGRAPHY; DOPED MATERIALS; ENZYME ACTIVITY; ENZYMES; MASS SPECTROSCOPY; POLYETHYLENE GLYCOLS; SILICA
Descriptors DEC
ALCOHOLS; GLYCOLS; HYDROXY COMPOUNDS; MATERIALS; MINERALS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; OXIDE MINERALS; POLYMERS; PROTEINS; SEPARATION PROCESSES; SPECTROSCOPY

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.