Resistor cooling in a vacuum

Description

This note describes thermal measurements which were done on a resistor operating both in air at one atmosphere pressure and in a vacuum of a few milliTorr. The motivation for this measurement was our interest in operating a BGO crystal-photomultiplier tube-base assembly in a vacuum, as a synchrotron radiation detector to tag electrons in the MT beam. We wished to determine what fraction of the total resistor power was dissipated by convection in air, in order to know whether there would be excessive heating of the detector assembly in a vacuum. 3 figs

Availability note (English)

Available from NTIS, PC A02/MF A01; 1 as DE88000696.

Files

19023219.pdf

Files (269.3 kB)

Name Size Download all
md5:f1c8d9e2b73e87d44e04f170e6d7dfb0
269.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
FNAL-TM--1468

Optional Information

Notes
Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted.