Performance and Aging Studies of BaBar Resistive Plate Chambers

Description

The BaBar detector is currently operating nearly 200 Resistive Plate Chambers (RPCs), constructed as part of an upgrade of the forward endcap muon detector in 2002. Although the average RPC efficiency remains high, numerous changes in the RPC performance (increased currents and rates) have been observed. A few of the highest rate RPCs have suffered efficiency losses of more than 15%. Several types of efficiency loss have been observed. Tests with humidified gas have shown that some of the lost efficiency is recoverable. However, efficiency losses in the highest rate regions have not yet improved with humid gases

Availability note (English)

Available from http://www.slac.stanford.edu/cgi-wrap/getdoc/slac-pub-12157.pdf; http://www.slac.stanford.edu/cgi-wrap/pubpage?slac-pub-12157.html; PURL: https://www.osti.gov/servlets/purl/893298-5SKu8g/

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
SLAC-PUB--12157

Conference

Title
8. Workshop on Resistive Plate Chambers and Related Detectors
Dates
10-12 Oct 2005
Place
Seoul (Korea, Republic of)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
38005934
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
AGING; EFFICIENCY; GASES; MUONS; PERFORMANCE; PLATES
Descriptors DEC
ELEMENTARY PARTICLES; FERMIONS; FLUIDS; LEPTONS

Optional Information

Contract/Grant/Project number
AC02-76SF00515
Notes
Nucl.Phys.Proc.Suppl.158:139-142,2006
Funding organization
US Department of Energy (United States)