Published December 2011 | Version v1
Journal article

Current and voltage measurements of light II-B pulsed power generator

  • 1. China Institute of Atomic Energy, Beijing (China)

Description

According to the coaxial cylindrical structure of PTL on Light II-B pulsed power source, a capacitive voltage divider was designed in the end of the PTL as pulsed voltage monitor. A stainless steel film connecting the outer tube and load was designed as pulsed current monitor, and the process was simulated using the circuit software. The probes of the capacitive voltage divider and the current monitor were calibrated on line, so the capacitive voltage divider and the current monitor could calibrate the high pulsed voltage and the current nicely. The results show that the capacitive voltage divider and the current monitor are ideal probes for measuring high pulsed voltage and current. (authors)

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
45
Journal Issue
12
Journal Page Range
p. 1502-1505
ISSN
1000-6931

Optional Information

Notes
8 figs., 1 tabs., 6 refs.