A wide band damper system has been developed for the Fermilab Antiproton Source. The system includes both forward and reverse beam direction damping in the Accumulator and forward only in the Debuncher. The system is currently used to damp coherent instabilities in the Accumulator during antiproton accumulation and extraction. The Damper system is also useful as a diagnostic tool. This paper includes some details about the design of the system hardware. Specifically included are the design of the beam pickup preamplifiers, a correlator notch filter and 300 Watt 1800 power splitters. Also included are measurements made to verify the system is working properly

Additional details

Publishing Information

Publisher
IEEE Service Center.
Imprint Place
Piscataway, NJ (USA)
Imprint Title
Proceedings of the 1987 IEEE particle accelerator conference: Accelerator engineering and technology
Journal Page Range
p. 791.

Conference

Title
Particle accelerator conference.
Dates
16-19 Mar 1987.
Place
Washington, DC (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19084210
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANTIPROTON BEAMS; DAMPING; FERMILAB ACCELERATOR; SPECIFICATIONS
Descriptors DEC
ACCELERATORS; ANTINUCLEON BEAMS; ANTIPARTICLE BEAMS; BEAMS; CYCLIC ACCELERATORS; SYNCHROTRONS