Published October 1, 1999 | Version v1
Report

The measurement of the optical cavity length for the Infrared Free-Electron Laser

Description

One of the final tasks involved in the alignment of the newly constructed Free Electron Laser at the Thomas Jefferson National Accelerator Facility was to accurately measure the length between two mirrors which make up the optical cavity. This presentation examines the survey techniques and equipment assembled in order to complete these measurements, together with the possible sources of error, and the accuracy achieved

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/754629-exFJea/webviewable/

Additional details

Publishing Information

Imprint Pagination
692 Kilobytes
Report number
DOE/ER--40150-1296

Conference

Title
International Workshop on Accelerator Alignmen
Acronym
IWAA 99
Dates
18-21 Oct 1999
Place
Grenoble (France)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
31029491
Subject category
S42: ENGINEERING; S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ALIGNMENT; CEBAF ACCELERATOR; FREE ELECTRON LASERS; LASER CAVITIES; LASER MIRRORS; LENGTH; MEASURING METHODS
Descriptors DEC
ACCELERATORS; DIMENSIONS; LASERS; LINEAR ACCELERATORS; MIRRORS

Optional Information

Contract/Grant/Project number
AC05-84ER40150
Funding organization
USDOE Office of Energy Research (ER) (United States)
Secondary number(s)
JLAB-ACE--99-09