Published November 30, 2006 | Version v1
Journal article

Impact of the 'non-destructive' multiple-readout on the Lorentzian noise

  • 1. Politecnico di Milano, P.za Leonardo da Vinci 32, 20133 Milan (Italy) and INFN, Sezione di Milan (Italy)
  • 2. INFN, Sezione di Milan (Italy)
  • 3. Politecnico di Milano, P.za Leonardo da Vinci 32, 20133 Milan (Italy)

Description

In this paper, we discuss the effect of 'non-destructive' multiple-readout on the Lorentzian noise. To our knowledge, it is the first time that such interaction is investigated. We have studied the peculiarities of the shape of the optimum weighting function for the multiple-readout technique in the presence of Lorentzian noise and other noise sources. The impact of the Lorentzian noise on the resolution achievable with the multiple-readout technique is analyzed in detail with respect to the interaction between the oscillation time and the characteristic time constant of the Lorentzian noise

Additional details

Identifiers

DOI
10.1016/j.nima.2006.06.002;
PII
S0168-9002(06)01125-9;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
568
Journal Issue
1
Journal Page Range
p. 329-335
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
10. European symposium on semiconductor detectors
Dates
12-16 Jun 2005
Place
Wildbad Kreuth (Germany)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38037293
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DAMAGE; FILTERS; NOISE; OSCILLATIONS; READOUT SYSTEMS; RESOLUTION; SPECTROSCOPY; WEIGHTING FUNCTIONS
Descriptors DEC
FUNCTIONS

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.