The effect of a hypothetical reduction of the SOL power width on the performance of the ITER divertor is analyzed using the SOLPS4.3 code. A reduction of this width by a factor 3 (down to 1.2 mm) is found to increase the peak power load only by a factor 1.6 because power dissipation in the partially detached divertor plasma is enhanced. The operating window is smaller, but still exists at 10 MW/m2 power load. Full alpha particle power is recovered if the allowed peak power load is a factor 1.5 higher, albeit at reduced Q which still remains above Q = 10

Availability note (English)

Available from http://dx.doi.org/10.1016/j.jnucmat.2013.01.027

Additional details

Identifiers

DOI
10.1016/j.jnucmat.2013.01.027;
PII
S0022-3115(13)00035-4;

Publishing Information

Journal Title
Journal of Nuclear Materials
Journal Volume
438
Journal Issue
Suppl
Journal Page Range
p. S203-S207
ISSN
0022-3115
CODEN
JNUMAM

Conference

Title
20. international conference on plasma-surface interactions in controlled fusion devices
Acronym
PSI-20
Dates
21-25 May 2012
Place
Aachen (Germany)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45067452
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALPHA PARTICLES; DIVERTORS; ITER TOKAMAK; PEAK LOAD; PLASMA
Descriptors DEC
CHARGED PARTICLES; CLOSED PLASMA DEVICES; IONIZING RADIATIONS; RADIATIONS; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTORS; TOKAMAK DEVICES; TOKAMAK TYPE REACTORS

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.