Results on developing the maximum compact synchrotron (average radius R=L/2π=2.15 m, L - perimeter of the orbit) for regional centers of proton beam therapy on the proton energy of 200 MeV are presented. Such a compact arrangement of the accelerator equipment enables to use the radiation protected buildings for regional centers in a number of cases. The RFQ linear accelerator on the energy of 3 MeV is proposed to be used as an injector. The extraction, proposed by developing medicine synchrotrons, significantly decreases the angular spread of the extracted particles and their losses on the septum. It allows to achieve the extraction coefficient of ∼ 90%. Four low-field multipole lenses with independent windings supply, creating dipole, quadrupole and sextupole components of the field with different orientation, were proposed for the field correction
Abstract (Russian)
Представлены результаты разработки предельно компактного синхротрона (средний радиус R=L2π=2.15 m, L - периметр орбиты) для региональных центров протонно-лучевой терапии на энергию протонов 200 МэВ. Такая плотная компоновка обрудования ускорителя позволяет в ряде случаев использовать для региональных центров существующие радиационно защищенные помещения. В качестве инжектора предлагается использовать линейный RFQ ускоритель на энергию 3 МэВ. Вывод, предложенный при разработке медицинских синхротронов, значительно уменьшает угловой разброс выводимых частиц и их потери на септуме. Это позволяет получить коэффициент вывода ∼ 90%. Для коррекции поля предлагается использовать четыре низкополевые мультипольные линзы с независимым питанием обмоток, создающих дипольные, квадрупольные и секступольные компоненты поля с различной ориентациейAdditional details
Additional titles
- Original title (Russian)
- Компактный синхротрон для региональных центров протонно-лучевой терапии
Publishing Information
- Publisher
- GNTs RF IFVEh
- Imprint Place
- Protvino, Moskovskaya Oblast' (Russian Federation)
- ISBN
- 5-88738-036-5; 5-88738-034-9
- Imprint Title
- 17. Conference on the charged particle accelerators. Collection of reports in two volumes. Vol. 2
- Imprint Pagination
- 420 p.
- Journal Page Range
- p. 329-332
Conference
- Title
- 17. Conference on the charged particle accelerators
- Original Conference Title
- 17. Soveshchanie po uskoritelyam zaryazhennykh chastits
- Dates
- 17-20 Oct 2000
- Place
- Protvino, Moskovskaya Oblast' (Russian Federation)
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 34008897
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM EXTRACTION; CORRECTIONS; ELECTROMAGNETIC LENSES; ION BEAM INJECTION; MAGNETIC FIELDS; MEV RANGE 100-1000; PROTON BEAMS; RADIOTHERAPY; SPECIFICATIONS; SYNCHROTRONS
- Descriptors DEC
- ACCELERATORS; BEAM INJECTION; BEAMS; CYCLIC ACCELERATORS; ENERGY RANGE; LENSES; MEDICINE; MEV RANGE; NUCLEAR MEDICINE; NUCLEON BEAMS; PARTICLE BEAMS; RADIOLOGY; THERAPY
Optional Information
- Notes
- 6 refs., 2 figs., 1 tab. Imprint:17. Soveshchanie po uskoritelyam zaryazhennykh chastits. Sbornik dokladov v 2-kh tomakh. Tom 2