First results of the soft X-ray microfocus beamline U41-PGM
Description
We present the first experimental data obtained from the new microfocus beamline U41-PGM recently put into operation. The optical layout of the beamline has been designed to conserve the high spectral brillance of the undulator source. The beamline consists of a collimated plane grating monochromator (PGM) and a subsequent refocusing stage. A toroidal mirror is used for refocusing onto the sample surface. With the 600 1/mm grating an absolute photon flux between 1012 and 1013 photons per second has been recorded over the whole energy range. Although the monochromator is not designed to deliver highest energy resolution, a resolving power of up to 6000 at the nitrogen K-edge has been obtained recently. The fixfocus constant cff is variable in a wide range. According to the experimental requirements it can be set to select either high photon flux or energy resolution
Additional details
Identifiers
- PII
- S016890020100376X;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 467-468
- Journal Issue
- 1-2
- Journal Page Range
- p. 485-487
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Germany
- INIS RN
- 33062791
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM OPTICS; BEAM TRANSPORT; COLLIMATORS; DIFFRACTION GRATINGS; ENERGY RESOLUTION; FOCUSING; MIRRORS; MONOCHROMATORS; ONDULATOR RADIATION; OPTICAL SYSTEMS; PHOTON BEAMS; RADIATION FLUX; SOFT X RADIATION; SYNCHROTRON RADIATION SOURCES
- Descriptors DEC
- BEAMS; BREMSSTRAHLUNG; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATION SOURCES; RADIATIONS; RESOLUTION; X RADIATION
Optional Information
- Copyright
- Copyright (c) 2001 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.