Published February 1987 | Version v1
Journal article

Problems in signal-to-noise ratio for attenuation correction in high resolution PET

  • 1. Div. of Nuclear Medicine and Biophysics, Dept. of Radiological Sciences, UCLA School of Medicine, Los Angeles, CA 90024

Description

In high resolution PET, the number of events required for a high signal-to-noise ratio in the measured attenuation correction is an order of magnitude higher (50-100 million) than that required for the emission image. This is due to the large number of elements in the attenuation correction sinogram (e.g. 50,000) and the large attenuation factors through the thicker sections of the body (e.g. 50). Another major contribution to noise in high resolution PET is contamination of true coincidences by accidentals and their subtraction from the prompt coincidences. In this work three methods which reduce noise in the measured attenuation are evaluated. The methods are: (1) optimization of energy threshold, (2) processing of random sinogram before subtraction and (3) spatial averaging of the transmission sinogram before performing attenuation correction

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
NS-34
Journal Issue
1
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
288-293
ISSN
0018-9499
CODEN
IETNA

Conference

Title
Nuclear science and nuclear power systems symposium.
Dates
29-31 Oct 1986.
Place
Washington, DC (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
18060730
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ATTENUATION; CORRECTIONS; DATA PROCESSING; DIAGRAMS; IMAGES; POSITRON COMPUTED TOMOGRAPHY; RESOLUTION; SIGNAL-TO-NOISE RATIO; THICKNESS; THRESHOLD ENERGY
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIMENSIONS; EMISSION COMPUTED TOMOGRAPHY; ENERGY; INFORMATION; TOMOGRAPHY

Optional Information

Secondary number(s)
CONF-861007--.