Published January 2012 | Version v1
Journal article

Decrease of the lumpectomy cavity volume after whole-breast irradiation affects small field boost planning

  • 1. Northwest Radiation Oncology and Division of Oncology, UT Medical School at Houston, Houston, TX (United States)
  • 2. Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States)
  • 3. Princeton Radiology, Princeton, NJ (United States)

Description

To determine whether small field boost (SFB) replanning is necessary when the lumpectomy cavity (LPC) decreases during whole-breast irradiation (WBI) and what parameters might predict a change in the SFB plan. Forty patients had computed tomography (CT) simulation (CT1) within 60 days of surgery and were resimulated (CT2) after 37.8–41.4 Gy for SFB planning. A 3-field photon plan and a single en face electron plan were created on both CTs and compared. In the 26 patients who had a ≥5 cm3 and a ≥25% decrease in lumpectomy cavity volume (LCV) between CT scans, the SFB plan using photons was different in terms of normal breast tissue volume irradiated (BTV) (p < 0.001), and field dimensions (p < 0.001). In 20/35 patients, the energy or field size changed for electron plans on CT2, but no tested characteristics predicted for a change. Less BTV was irradiated using electrons than photons in 29% (CT1) to 37% (CT2). SFB replanning needs to be individualized to each patient because of the variety of factors that can impact dosimetric planning. Replanning is recommended when using 3-field photons if the patient has experienced a ≥5 cm3 and a ≥25% decrease in LCV during WBI. Some patients may benefit from electron SFB replanning but no tested characteristics reliably predict those who may benefit the most. The amount of BTV irradiated is less with electrons than in photon plans and this has the potential to improve cosmesis, a clinically important outcome in breast-conserving therapy.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.meddos.2011.11.008

Additional details

Identifiers

DOI
10.1016/j.meddos.2011.11.008;
PII
S0958-3947(11)00214-7;

Publishing Information

Journal Title
Medical Dosimetry
Journal Volume
37
Journal Issue
3
Journal Page Range
p. 339-343
ISSN
0958-3947

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44086369
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
CAT SCANNING; CAVITIES; DOSIMETRY; ELECTRONS; IRRADIATION; MAMMARY GLANDS; PATIENTS; PHOTONS; PLANNING; RADIOTHERAPY; SIMULATION; SURGERY
Descriptors DEC
BODY; BOSONS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; ELEMENTARY PARTICLES; FERMIONS; GLANDS; LEPTONS; MASSLESS PARTICLES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.