Analysis and improvement of control logic for entrance isolation valve in RRA system

  • 1. Suzhou Nuclear Power Institute Co., Ltd., Suzhou (China)

Description

Because of the origin design for control logic of entrance isolation valve in RRA system was not conform to the single failure criterion, the improvement scheme, which would be added two sets of pressure transmitter, has been raised. The effect of RRA system and the damage of reactor core have been evaluated through quantitative calculation about the scheme of the modification. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
36
Journal Issue
3
Journal Page Range
p. 88-89
ISSN
0258-0926

Optional Information

Notes
2 figs., 1 ref.