Published September 1968 | Version v1
Report Open

Weak current measurement. Application to the determination of exposure doses

  • 1. Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires

Description

This article outlines a method for the absolute measurement of weak currents produced in an ionisation chamber. The measuring assembly consists basically of cavity ionisation chambers connected to an electro-metric device. When used to measure exposure dose rates, this apparatus can cover a range from 10 milli-roentgens/hour to 15000 roentgens/hour. (author)

Availability note (English)

Available from INIS in electronic form

Abstract (French)

Dans cet article, nous etudions une methode de mesure absolue de courants faibles issus de chambre d'ionisation. Nous decrivons un ensemble de mesure constitue essentiellement de chambres d'ionisation a cavite associees a un dispositif electronique. En appliquant ce dispositif a la mesure des debits d'exposition, on peut couvrir un domaine de 10 milli-roentgens/ heure a 15000 roentgens/heure. (auteur)

Files

35091422.pdf

Files (246.2 kB)

Name Size Download all
md5:284c8d21ccbb3d81c7641932353c3a93
246.2 kB Preview Download

Additional details

Additional titles

Original title (French)
Mesure de courants faibles application a la determination des debits d'exposition

Publishing Information

Imprint Pagination
[15 p.]
Report number
CEA-R--3584

Optional Information

Notes
4 refs.