Inadequate core cooling monitoring system improvement
Description
The Inadequate Core Cooling Monitoring System (ICCMS) is a safety-related monitoring system which calculates variables associated with Inadequate Core Cooling (ICC) and provides the ICC related information to the reactor operator for monitoring of the status of core cooling during the accident. The improved ICCMS equipped industrial computer therefore independently accomplish the ICCM algorithm which existed as a sub-module of the Plant Data Acquisition System (PDAS) in the existing nuclear power plants and have a improved color Graphic User Interface (GUI) by which the operator can read information more easily and intuitively. Also the improved ICCMS was developed using modern techniques like C/C++ programming language to be consistent with modern system environment. This paper explains the improved features of ICCMS and improvement effects
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the Korean Nuclear Society autumn meeting
- Imprint Pagination
- [CD-ROM]
- Journal Page Range
- [9 p.]
Conference
- Title
- 2001 autumn meeting of the Korean Nuclear Society
- Dates
- 24-26 Oct 2001
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 33065405
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPUTER GRAPHICS; COOLING SYSTEMS; DATA ACQUISITION SYSTEMS; INTERFACES; NUCLEAR POWER PLANTS; REACTOR CORES; REACTOR MONITORING SYSTEMS
- Descriptors DEC
- ENERGY SYSTEMS; NUCLEAR FACILITIES; POWER PLANTS; REACTOR COMPONENTS; THERMAL POWER PLANTS
Optional Information
- Notes
- 4 refs, 5 figs, 1 tab