Published March 1987 | Version v1
Report Restricted

Feedwater transient and small break loss of coolant accident analyses for the Bellefonte Nuclear Plant

Description

Specific sequences that may lead to core damage were analyzed for the Bellefonte nuclear plant as part of the US Nuclear Regulatory Commission's Severe Accident Sequence Analysis Program. The RELAP5, SCDAP, and SCDAP/RELAP5 computer codes were used in the analyses. The two main initiating events investigated were a loss of all feedwater to the steam generators and a small cold leg break loss of coolant accident. The transients of primary interest within these categories were the TMLB' and S2D sequences. Variations on systems availability were also investigated. Possible operator actions that could prevent or delay core damage were identified, and two were investigated for a small break transient. All of the transients were analyzed until either core damage began or long-term decay heat removal was established. The analyses showed that for the sequences considered the injection flow from one high-pressure injection pump was necessary and sufficient to prevent core damage in the absence of operator actions. Operator actions were able to prevent core damage in the S2D sequence; no operator actions were available to prevent core damage in the TMLB' sequence

Availability note (English)

Available from NTIS, PC A06/MF A01 - GPO as TI87007172.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
117 p.
Report number
NUREG/CR--4741

Optional Information

Secondary number(s)
EGG--2471.