Published June 2009 | Version v1
Report

Development of detectors to identify RI beams

  • 1. Univ. of Tsukuba, Graduate School of Pure and Applied Sciences, Tsukuba, Ibaraki (Japan)

Description

With a 400 A MeV Kr beam, rate dependences of energy resolution for tilted electrode gas ion chamber (TEGIC) have been measured. At the same time, we checked performance for LYSO crystals by using the Kr beam with a low rate. (author)

Part of:
2008 Annual report of the research project with heavy ions at NIRS-HIMAC

Additional details

Publishing Information

Imprint Title
2008 Annual report of the research project with heavy ions at NIRS-HIMAC
Imprint Pagination
349 p.
Journal Page Range
p. 281-282
Report number
NIRS-M--226

Optional Information

Notes
This record replaces 44074494