Thyroid uptake of [/sup 99m/Tc] pertechnetate during in vivo RBC labeling: incidental diagnosis of hypothyroidism

  • 1. The Univ. of Iowa Hospitals and Clinics, Iowa City

Description

Increased thyroid activity was incidentally observed during an in vivo labeled Tc-99m blood pool scan and subsequent evaluation resulted in a diagnosis of hypothyroidism. Alternate explanations of abnormal thyroid uptake on in vivo labeled blood pool scans were considered and are discussed briefly