Published November 2001 | Version v1
Report

The development and application of overheating failure model of FBR steam generator tubes. 2

  • 1. Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center
  • 2. Japan Nuclear Cycle Development Inst., Tokyo Office, Plant Improvement Planning Group, Tokyo (Japan)

Description

The JNC technical report 'The Development and Application of Overheating Failure Model of FBR Steam Generator Tubes' summarized the assessment method and its application for the overheating tube failure in an event of sodium-water reaction accident of fast breeder reactor's steam generators (SGs). This report describes the following items studied after the publication of the above technical report. 1. On the basis of the SWAT-3 experimental data, realistic local heating conditions (reaction zone temperature and related heat transfer conditions) for the sodium-water reaction were proposed. New correlations are cosine-shaped temperature profiles with 1,170 C maximum for the 100% and 40% Monju operating conditions, and those with 1,110 C maximum for the 10% condition. 2. For the cooling effects inside of target tubes, LWR's studies of critical heat flux (CHF) and post-CHF heat transfer correlations have been examined and considered in the assessment. The revised assessment adopts the Katto's correlation for CHF, and the Condie-Bengston IV correlation for post-CHF. 3. Other additional examination for the assessment includes treatments of the whole heating effect (other than the local reaction zone) due to the sodium-water reaction, and the temperature-dependent thermal properties of the heat transfer tube material (2.25Cr-1Mo steel). The revised overheating tube failure assessment method has been applied to the Monju SG studies. It is revealed consequently that no tube failure occurs in 100%, 40%, and 10% operating conditions when an initial leak is detected by the cover gas pressure detection system. The assessment for the SG system improved for the detection and blowdown systems shows even better safety margins against the overheating tube failure. (author)

Availability note (English)

Available from JICST Library (JICST: Japan Science and Technology Corporation, Information Center for Science and Technology), P.O. Box 10 Hikarigaoka, Tokyo 179-9810 Japan, FAX: +81-3-3979-4781 (domestic), FAX: +81-3-3979-2210 (oversea)

Additional details

Publishing Information

Imprint Pagination
78 p.
Report number
JNC-TN--9400-2001-099

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
33029583
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
EVALUATION; FAILURES; FBR TYPE REACTORS; HYDRAULICS; LEAKS; MOLTEN METAL-WATER REACTIONS; NUMERICAL ANALYSIS; STEAM GENERATORS; TEMPERATURE DISTRIBUTION; THERMODYNAMICS; TUBES
Descriptors DEC
BOILERS; BREEDER REACTORS; EPITHERMAL REACTORS; FAST REACTORS; FLUID MECHANICS; MATHEMATICS; MECHANICS; REACTORS; VAPOR GENERATORS

Optional Information

Notes
23 refs., 40 figs., 11 tabs.