Design of KIRAMS-13 RF system for regional cyclotron center
Creators
- 1. Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)
Description
The KIRAMS-13 has been improved for regional cyclotron center for the last five years. The magnet design was changed to reduce electric power consumption. The length of a pole gap was shorted by 20mm and number of coil turns was increased to 16x19. So, electric power consumption of magnet system was reduced about 67%. And the magnetic field influenced the central region design because the beam trajectory was changed. But, main RF parameters, such as resonant frequency, RF power, dee structure, cavity structure, and so on, were not changed to reduce production cost and time. Consequently, we had to consider the RF system design as a result of changing the magnet design and the central region design. For satisfying these preconditions, we only redesigned the liner and the central region of KIRAMS-13
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS autumn meeting
- Imprint Pagination
- 1466 p.
- Journal Page Range
- p. 1263-1264
Conference
- Title
- 2004 autumn meeting of the KNS
- Dates
- 28-29 Oct 2004
- Place
- Yongpyong (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36102637
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CYCLOTRONS; DESIGN; ELECTRIC POWER; MAGNETIC FIELDS; MAGNETS; SPECIFICATIONS
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; EQUIPMENT; POWER
Optional Information
- Notes
- 4 refs, 9 figs, 1 tab